69kV nominal voltage 40kA maximum symmetrical interrupting capability 1200A maximum continuous current Capable of -40?C operation without tank heaters 73 inch creep porcelain bushings rated 350kV BIL @ 3300 feet ASL,3 cycle, 60Hz, spring-spring operated Independent pole Operation, Common Frame mounted outdoor Circuit Breaker, With PSD (synchronous controller), Bushing Current Transformers (total 12 BCT?s), Bushings 1-3-5: (6) 600:5 MR C400, MR RF 2.0, Bushings 2-4-6: (6) 600:5 MR C400, MR RF 2.0, Synchronous controller shall be factory installed in the breaker main control cabinet, Control and Operator Power Requirements, Control supply voltage 125 VDC, Spring charge motor supply voltage 125VDC, Accessory supply voltage 120 VAC, Heater supply voltage: 120 VAC, Options Included: Fused knife switches (close / motor / heater circuits), One close coil, two trip coil, Temperature compensated density switch and gauge per pole, Control switch, Local / remote selector switch, LED position indicator lights, Emergency trip, Cabinet light with guard and door activated switch, GFCI duplex outlet in control cabinet, Thermostatically controlled cabinet heaters, Auxiliary switches with 8a and 8b spare contacts for customer use, Trip circuit monitoring, Anodized aluminum nameplates according to IEEE/ANSI standards, #14 AWG Type SIS control wiring, NEMA 4-hole tin-plated aluminum terminals, NEMA type 3R control cabinet, Standard installation toolkit included, SF6 fill gas included. New cost $232,974
  • General
  • Photos

Auction Date & Time

For Immediate Sale

Canada/Pacific

Location

Okanagan Falls

2019
Siemens
SPS2-72-40-1200-IPO
High Voltage Circuit Breakers

69kV nominal voltage 40kA maximum symmetrical interrupting capability 1200A maximum continuous current Capable of -40?C operation without tank heaters 73 inch creep porcelain bushings rated 350kV BIL @ 3300 feet ASL,3 cycle, 60Hz, spring-spring operated Independent pole Operation, Common Frame mounted outdoor Circuit Breaker, With PSD (synchronous controller), Bushing Current Transformers (total 12 BCT?s), Bushings 1-3-5: (6) 600:5 MR C400, MR RF 2.0, Bushings 2-4-6: (6) 600:5 MR C400, MR RF 2.0, Synchronous controller shall be factory installed in the breaker main control cabinet, Control and Operator Power Requirements, Control supply voltage 125 VDC, Spring charge motor supply voltage 125VDC, Accessory supply voltage 120 VAC, Heater supply voltage: 120 VAC, Options Included: Fused knife switches (close / motor / heater circuits), One close coil, two trip coil, Temperature compensated density switch and gauge per pole, Control switch, Local / remote selector switch, LED position indicator lights, Emergency trip, Cabinet light with guard and door activated switch, GFCI duplex outlet in control cabinet, Thermostatically controlled cabinet heaters, Auxiliary switches with 8a and 8b spare contacts for customer use, Trip circuit monitoring, Anodized aluminum nameplates according to IEEE/ANSI standards, #14 AWG Type SIS control wiring, NEMA 4-hole tin-plated aluminum terminals, NEMA type 3R control cabinet, Standard installation toolkit included, SF6 fill gas included. New cost $232,974

Additional Information

Linked Document